Model
|
TAC30-3/R
|
TAC30-3D
|
TAC30-6/R
|
TAC60-3R
|
Output
|
|
Output
voltage |
0 to 30V |
0 to 30V
(x2) |
0 to 30V |
0 to 60V |
|
Output
current |
0 to 3A |
0 to 3A
(x2) |
0 to 6A |
0 to 3A |
|
Constant
voltage characteristics |
|
Input
regulation |
For AC ±10%
fluctuation |
5mV |
8mV |
5mV |
8mV |
|
Load
regulation |
For 0 to
100% fluctuation |
5mV |
8mV |
5mV |
8mV |
|
Ripple and
noise |
10Hz to 1MHz |
0.5mV rms |
0.5mV rms,
|
1mV rms |
1mV rms |
|
Ripple peak |
10Hz to
20MHz |
4m Vp-p |
4mVp-p |
4m Vp-p |
4m Vp-p |
|
Transient
response |
Standard
value (current 5%to100%) |
50µ Typical |
50µ Typical |
50µ Typical |
50µ Typical |
|
Temperature
coefficient |
Standard
value |
100ppm/°C
Typical |
100ppm/°C
Typical |
100ppm/°C
Typical |
100ppm/°C
Typical |
|
Remote
control (TAC-R only) |
|
Controlled
by external voltage 0 to 10V |
Output
voltage |
0 to 30V±5% |
|
0 to 30V±5% |
0 to 60V±5% |
|
Controlled
by external resistance 0 to 10kW |
Output
voltage |
0 to 30V±5% |
|
0 to 30V±5% |
0 to 60V±5% |
Constant current characteristics
|
|
Input
regulation |
For AC ±10%
fluctuation |
2mA |
4mA |
6mA |
3mA |
|
Load
regulation |
For 0 to
100% fluctuation |
10mA |
10mA |
15mA |
15mA |
|
Ripple and
noise |
10Hz to 1MHz |
2mA rms |
3mA rms |
3mA rms |
2mA rms |
|
Temperature
coefficient |
Standard
value |
250ppm/°C
Typical |
250ppm/°C
Typical |
250ppm/°C
Typical |
250ppm/°C
Typical |
|
Remote
control (TAC-R only) |
|
Controlled
by external voltage 0 to 10V |
Output
voltage |
0 to 30A±5% |
|
0 to 6A±5% |
0 to 3A±5% |
|
Controlled
by external resistance 0 to 10kW |
Output
voltage |
0 to 30A±5% |
|
0 to 6A±5% |
0 to 3A±5% |
|
Constant
voltage operation indication |
CV (green
LED) lights |
|
CV (green
LED) lights |
CV (green
LED) lights |
|
Constant
current operation indication |
OC (red LED)
lights |
|
OC (red LED)
lights |
OC (red LED)
lights |
Digital meter indication
|
|
Voltmeter
indication |
Red 3-digit
LED |
Max.99.9V,
fixed range |
Max.99.9V,
fixed range |
Max.99.9V,
fixed range |
Max.99.9V,
fixed range |
|
Accuracy |
Output ON |
±(0.2%
rdg+2digits) |
±(0.2%
rdg+2digits) |
±(0.2%
rdg+2digits) |
±(0.2%
rdg+2digits) |
|
Ammeter
indication |
Red 3-digit
LED |
Max.99.9V,
fixed range |
Max.99.9V,
fixed range |
Max.99.9V,
fixed range |
Max.99.9V,
fixed range |
|
Accuracy |
Output ON |
±(1.0%
rdg+3digits) |
±(1.0%
rdg+3digits) |
±(1.0%
rdg+3digits) |
±(1.0%
rdg+3digits) |
Functions
|
|
Output
ON/OFF |
Output
on/off is possible (Remote control is possible only for the TAC-R series) |
|
Remote (TAC-R
only) |
|
Remote
sensing |
TAC-R series
only |
Possible by
using the (+S) and (-S) terminals on the panel.
Compensation
possible up to 1V one way. |
|
Series
operation |
Master/slave
mode, TAC-R series only |
One control
series operation is possible (within the ground proof voltage). |
|
Parallel
operation |
Master/slave
mode, TAC-R series only |
One control
parallel operation is possible (only for the same models) |
|
Operating
conditions (Indoor use only) |
|
Altitude |
Up to 2000m |
|
Over voltage
category |
Category 2 |
|
Operating
temperature and humidity range |
0 to 40°C 10
to 80%RH |
|
Storage
temperature and humidity range |
-20 to 60°C
10 to 85%RH |
|
Cooling
method |
Natural air
cooling |
|
Output
polarity |
+(red),
-white), GND(black), *grounding possible |
|
Ground proof
voltage |
±200V |
|
Insulation
resistance
|
Between
chassis and input supply |
DC500V 30MW |
|
Between
chassis and input terminal |
DC500V 20MW |
Power
|
|
Input power
|
Voltage
fluctuation:within ±10% |
AC100V/120V/220V/230V, selectable |
|
(Approx.) |
235VA/165W |
|
450VA/370W |
380VA/300W |
Dimension, weight
|
|
Dimension (WxHxD)mm |
134x147x322 |
234x160x326mm |
210x147x324 |
210x146x324 |
|
Max.
dimensions (WxHxD)mm |
138x162x345 |
|
210x163x347 |
210x163x347 |
|
Weight (kg) |
6.6 |
7.5 |
10 |
10 |
|
Accessories |
Instruction
manual (1), power cable (1) |