Complies with Power Supply Harmonics Current Regulation, and a Power
Factor of 95% (typical)
The PDS Series comply with Power Supply Harmonics Current Regulations
(IEC1000-3-2) as well as "Home Appliance and General-Purpose Products
Harmonics Suppression Control Guidelines", and never affect the AC
supply due to current harmonics. Furthermore with a built-in active
smoothing filter, a resulting power factor of 95% (typical) is cleared.
●
Satisfying CE Mark Certification Requirements
These models satisfy Low-Voltage Standards (IEC1010) and EMC Standards
Requirements.
●
Series/Parallel Operation
When these models are connected in series, the resulting output voltage
is increased. And when they are connected in parallel, the resulting
output current is increased. For more convenience, when a master-slave
system is used, either a series drive or a parallel drive operation can
be performed by a single unit in order to control the output of all of
the other units.
(A master-slave system is possible with up to 3 units in parallel mode,
and up to 2 units in series mode.)
●
Voltage/Current Simultaneous Digital Display
The bright and easy-to-see displays with 7-segment red LEDs are designed
to display the voltage and current values digitally at the same time.
●
Voltage/Current Preset (3 points)
The frequently used output values for voltage and current can be stored
in the memory for up to 3 points for each value. The preset values can
be recalled with a touch of a button, making possible the switching of
the output value more quickly.
●
Single-Dial Control Design
Designed with easy operation in mind, the operation conditions can be
set at a press of the push button switch, while all the setup values can
be changed using the rotary encoder control. Especially for output
voltage and current, high accuracy control is possible in 10 mV and 10
mA steps respectively. Furthermore, the variable speed of the control
knob can be switched between SLOW and FAST.
●
Key Lock Function
A key lock function is provided to fix the setup values for inhibiting
the operation on the front control panel. This is convenient when
long-term energization is required. Also, it is not necessary to have to
worry about mis-operation by others if you leave it on your desk while
the experiment is continuing.
●
Compact, Lightweight Design
When compared with the conventional PD-A Series, the weight is reduced
to 1/2 to 1/3. It can more easily be carried from door to door than
before.
●
Various Protection Functions
For protection, various protection functions are provided including OVP
(over-voltage protection), OHP (over-heating protection) and OCP
(over-current protection). When a protection circuit is engaged, the
power switch is automatically turned off.
●
Board-Type Options for External Control
External control is possible using optional board interface. Since a
board can be mounted inside the unit, no extra mounting space is
required. For external control, three types of options are available --
analog (voltage/resistor), GP-IB and RS-232C.
●
Worldwide AC Voltage Input Design
A wide range of AC power voltages can be input between 90 V and 264 V.
Each model is ready to accept worldwide power sources without switching
over the voltage selector.
●
Optional Accessories
GP-IB Interface Card : IF-30GP RS-232C Interface Card : IF-30RS Analog
Card : IF-30AN
Rack Mount Adapter : RK-605E (EIA size)
●
SPECIFICATIONS
| Model |
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
| Output |
| Output voltage range (V) |
0 - 20 |
0 - 20 |
0 - 36 |
0 - 36 |
0 - 60 |
0 -60 |
0 - 120 |
| Output current range (A) |
0 - 18 |
0 - 36 |
0 - 10 |
0 - 20 |
0 - 6 |
0 - 12 |
0 - 6 |
| Rated output power (W) |
360 |
720 |
360 |
720 |
360 |
720 |
720 |
| Output terminal |
Front & Rear |
Rear |
Front & Rear |
Rear |
Front |
Front |
Front |
| Model |
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
| Voltage regulation
characteristics |
| Line regulation |
0.005% 1 mV (for ± 10% source
voltage fluctuation) |
| Load regulation |
0.005% 2 mV (for 0 to 100%
fluctuation) |
| Ripple /noise‚ p-p (By 20MHz Scope) |
30 mVp-p |
| Ripple /noise‚ rms (5 Hz to 1 MHz) |
1 mVrms |
1.5 mVrms |
1 mVrms |
2 mVrms |
| Transient response (typ.) |
100µsec |
| Temperature coefficient (typ.) |
± 100 ppm/°C |
| Rise time (typ.) |
Full load / no load 100msec /
100msec |
| Fall time (typ.) |
Full load / no load 150msec /
1000msec |
| Model |
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
| Current regulation
characteristics |
| Line regulation |
5mA |
10mA |
1mA |
5mA |
1mA |
5mA |
1mA |
| Load regulation |
5mA |
| Ripple noise‚ rms (5 Hz to 1 MHz) |
10mA |
10mA |
5mA |
10mA |
5mA |
10mA |
5mA |
| Temperature coefficient |
± 100ppm/°C |
| Model |
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
| Display |
| Voltage display‚ accuracy (23±5°C) |
3 1/2 digits LED‚ 0.1% rdg ± 2
digits‚ 10mV accuracy |
| Current display‚ accuracy (23±5°C) |
3 1/2 digits LED‚ 0.5% rdg ± 2
digits‚ 10mA accuracy |
| In constant voltage/ current operation |
CV LED on/ CC LED on |
| Model |
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
| Output signals |
| Alarm signal output |
Open collector‚ active Low
Operation functions (5ms one pulse) |
| Model |
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
| Operation function |
| OVP key |
Displays OVP circuit operating
voltage on front panel‚ which is variable between 10 and 110% of
F.S. |
| KEYLOCK (LOCAL) key |
Locks keys and knobs (except POWER
switch). Also removes remote control. |
| PRESET 1 - 3 keys |
Used with MEM key to memorize three
output voltages and currents. |
| MEM key |
Used with PRESET keys to memorize
three output voltages and currents. |
| FAST/SLOW key |
Changes output voltage and current
setting speed. |
| ON/OFF control |
Enabled with input contact signals. |
| POWER switch shut-down |
Enabled with input contact signals. |
| Output voltage remote sensing |
Compensates for 1 V voltage drop on
single side. |
| Model |
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
| P rotection |
| Over voltage protection (OVP) |
POWER switch off at setting value |
| Over current protection (OCP) |
POWER switch off at setting value |
| Overheat protection (OHP) |
POWER switch off at setting value |
| Soft OVP (OVD) |
Set from external controller in
remote control mode. POWER switch off when soft OVP is active. |
| Model |
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
| Environmental request |
| Operating temperature / humidity range |
0 to 40 °C / 30 to 80 % RH |
| Stocking temperature / humidity range |
-20 to 70 °C / 20 to 80 % RH |
| To-GND voltage |
± 250 VDC |
| Cooling method |
Front air intake type forced air
cooling with fan motor Insulation resistance |
| Model |
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
| Power source |
| Input voltage |
AC 90 to AC 264 V‚ 50/60 Hz without
setting change. |
| Power factor (typ) |
95% |
| Power consumption (typ) |
560 W |
1100 W |
520 W |
1050 W |
520 W |
1050 W |
1050 W |
| Power efficiency (typ) |
65% |
65% |
70% |
70% |
72% |
72% |
72% |
| Model |
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
| Dimensions / Weight |
| Dimensions (W × H × D) mm |
210 × 124 × 405 |
210 × 124 × 405 |
| Maximum dimensions (W × H × D) mm |
210 × 141 × 465.5 |
210 × 141 × 217.5 |
| Weight (approx.) |
6.3 kg |
7.2 kg |
6.3 kg |
7.2 kg |
6.3 kg |
7.2 kg |
7.2 kg |
| Model |
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
| Options |
| Analog I/O board |
V/I controlled by external voltage
or resistance. |
| GP-IB interface board |
V/I set/read‚ Output ON/OFF‚ AC
shout down. |
| RS-232C interfaceboard |
V/I set/read‚ Output ON/OFF‚ AC
shout down. |
| Output capacity extension |
Parallel connection control :
Master-slave system‚ up to 3 units / Series connection control :
Master-slave system‚ up to 2 units |