SPECIFICATIONS |
| Frequency
Measurement (ch A) |
| Measurement Range/Unit |
kHz mode : 5 Hz -- 10 MHz/kHz
MHz mode : 5 Hz -- 100 MHz/kHz |
| Accuracy |
ア Reference time accuracy ア 1 count |
| Gate Time |
0.01 s 0.1 s 1 s 10 s |
| Frequency
Measurement (ch B) |
| Measurement Range/Unit |
80 MHz - 2400 MHz (2.4 GHz)/MHz |
| Accuracy |
ア Reference time accuracy ア 1 count |
| Gate Time |
0.032 s 0.32 s 3.2 s 32 s |
| Period Measurement (A) |
|
| Measurement Range |
0.04 オs - 200 ms (5 Hz -- 25 MHz) |
| Accuracy |
ア 1 count ア reference time accuracy
ア trigger error |
| Resolution |
10 ps -- 100 ns |
| Unit |
オsec. |
| Minimum Pulse Width |
0.04 オs |
| Magnification |
ラ 1 ラ 10 ラ 100 ラ 1000 |
| Pulse Width
Measurement (ch A) |
| Measurement Range |
0.25 オs -- 200 ms (5 Hz -- 2 MHz) |
| Resolution |
100 ps -- 100 ns |
| Accuracy |
ア 1 count ア reference time accuracy
ア trigger error ア N |
| Minimum Pulse Width |
250 オs |
| Unit |
オs. |
| Magnification |
ラ 1 ラ 10 ラ 100 ラ 1000 |
| Single Phenomenon |
Standby mode by resetting |
| Addition Counter
Measurement (A) |
| Counting Capacity |
0 - 99999999 |
| Measurement Range |
5 Hz - 10 MHz |
| Control |
Reset/Hold possible from front panel. Always ON
except when Start/Stop on the rear panel is set to LOW level. |
| Input
Characteristics (ch A) |
| Frequency Bandwidth |
5 Hz - 100 MHz AC coupling |
| Sensitivity (Sine Wave) |
kHz Freq. : 20 mVrms (5 Hz - 10 MHz)
MHz Freq. : 20 mVrms (5 MHz - 30 MHz)
50 mVrms (30 MHz -- 100 MHz) |
| Input Impedance |
1 MW 40 pF or less |
| Max. Input Voltage |
42 V (DC AC peak) |
| Attenuator |
ラ 1 (1/1) ラ 10 (1/10) |
| Low-Pass Filter |
100 kHz -3 dB |
| Input
Characteristics (ch B) |
| Frequency Bandwidth |
80 MHz -- 2.4 GHz AC coupling |
| Sensitivity (Sine Wave) |
5 mVrms (80 MHz -- 600 MHz)
15 mVrms (600 MHz -- 900 MHz)
35 mVrms (1.0 GHz -- 2.4 GHz) |
| Input Impedance |
50W |
| Max. Input Voltage |
1 Vrms |
| Reference
Oscillator |
| Oscillating Frequency (ch A B) |
10 MHz 1ラ 10-6 / 23 ア 5ーC |
| Stability (ch A B) |
1 ラ 10-6 / 0 to 40ーC (23ーC as a reference)
1 ラ 10-6 / year |
| Display |
| Display |
8 digits LED (7-segment)
kHz/オs MHz GATE OVER FLOW |
| Function Display |
FREQ A FREQ B PEIOD A
PULSE A TOTAL CHECK |
| Counting Time |
CH A: 0.01 s 0.1 s 1.0 s 10 s
CH B: 0.032s 0.32 s 3.2s 32 s |
| Self Check |
| Display |
Counting time base (Internal 10MHz) |
| Gate Time/Resolution |
0.01 s 0.1 s 1.0s 10s / 0.1 Hz - 100 Hz |
| Environmental
Condition |
| Storage Temperature/Humidity |
-20ーC to 60ーC 70% or less |
| Operation Temperature/Humidity |
0ーC to 40ーC 80% or less |
| Specification Guarantee Temperature/Humidity |
23ーC ア 5ーC 70% or less |
| Others |
| Power Requirements/Power Consumption |
AC 100/120/220/230 V ア 10%
50/60 Hz / Approx. 20 VA |
| Dimensions (W ラ H ラ D) |
240 ラ 64 ラ 190 mm
(260 ラ 70 ラ 210 mm, maximum dimensions) |
| Weight |
1.8 kg |
| Accessories |
Instruction Manual (1) Power Cable (1) |
| Applicable
Standard |
| EMI |
EN55011 (1991) Class B |
| EMS |
IEC801-2 (1991) 8kVAD, IEC801-3 (1984) 3 V/m,
IEC801-4 (1998) 1 kV,
5/50 オs, 5 kHz |