Home Up Contact On Line Order Site Map
T: +44 (0)1480 399499 e-mail:sales@tecstar.co.uk  www.tecstar.co.uk F: +44(0)1480 399503 
European distributor for Kenwood & Tecstar test and measurement, PrismSound audio analysers.

 

DCS-2000 Series Digital Oscilloscopes

DCS-2080 :   80MHz
           DCS-2150 : 150MHz                                                                                
           DCS-2250 : 250MHz
    25GS/s Sampling Rate per channel
    5.7 inch LCD Display
    Dual Digitiser
    USB, RS-232C, Printer interfaces
    FFT analysis
       32kBytes memory depth
 

The DCS-2000 Series Digital Oscilloscopes offer a wide range of bandwidths from 80MHz to 250MHz with a 25GS/s maximum equivalent time sampling rate, 32kBytes per channel of memory, 10ns peak detection for glitch capture, FFT (Fast Fourier Transform) function and an easy to-use, full featured user interface.

 The design incorporates a 16-bit high-speed microprocessor that enables it to acquire up to 150 waveforms per second and instantly update the waveform display. The large record memory (32kBytes) allows for high resolution capturing of long time events and captured waveforms with zoom for more detailed analysis. The built-in 10ns peak detection circuit facilitates the capture of high frequency noise at a low speed timebase. The waveform can then be magnified to analyse the noise using zoom-in function.

A communication module provides a USB, RS-232C interface and hardcopy printer. The USB function provides high-speed data communication, RS-232C provides a low cost interface. The DCS-2000 Series is ideally suited to applications in electronic design and development, education in colleges, universities and training centres, repair and maintenance, production, quality control and satisfies increasing needs of higher performance and reliability at an affordable price.

                                                                                                                                              

Description

DCS-2080

DCS-2150

DCS-2250

 

ACQUISITION

Max. Sample rate

200MS/s for one channel only, 100MS/s/CH (real time) 25GS/s/CH (equivalent)

Record length

Long Memory Max. 10kBytes/CH

Long Memory Max. 32kBytes/CH

Peak detect

Captures & displays as narrow as 10ns GLITCH

 

 

 

 

VERTICAL

Frequency bandwidth

DC-80MHz (40MHz at 2mV/div

DC-150MHz (40MHz at 2mV/div

DC-250MHz (60MHz at 2mV/div

Input Channel

CH1, CH2

VOLTS/DIV

2mV/div ~ 5V/div

Input impedance

1Mohm ±1.5% // Approx. 16pF

Max. Input volt

400V (DC+AC Peak) (AC < 1kHz)

Accuracy

±3%

Input coupling

DC, AC, GND

Rising time

Approx. 3.5ns

Approx. 2.3ns

Approx. 1.4ns

MATH

 

Arithmetic (ADD, SUBTRACT, INVERSION)

FFT : Hamming, Hanning and Rectangular Window

Pass-Fail : Editable waveform zone

 

 

HORIZONTAL

 

TIME/DIV

Equivalent : 2ns/div ~ 0.1µs/div

Real time : 0.25µs/div ~ 0.1 s/div

Roll mode : 0.2s/div ~ 5s/div

Resolution

80ps

Accuracy

0.01%

Pre trigger

Max. 10div

Magnification

ZOOM IN / OUT

 

 

 

TRIGGER

Mode

AUTO, NORMAL, SINGLE

Coupling

DC, AC, LF REJECT, HF REJECT

Type

Edge, TV

SLOPE

Rising, Falling

Level

Manual setting or Automatic 50% setting

Source

CH1, CH2, EXT, LINE

 

 

Sensitivity

 

TRIGGER

 

FREQUENCY

SENSITIVITY

5mV ~ 5V/div

2mV/div

INTERNAL

(CH1, CH2)

DC ~ 10MHz

0.5 div

0.5 div

10MHz ~ 80MHz

1.5 div

1.5 div

(at 10MHz ~ 40/60MHz)

80MHz ~ MAX. BW

2.0div

EXTERNAL

DC ~ MAX. BW

0.2Vp-p (0.5Vp-p at 150MHz ~ 250MHz)

DISPLAY

 

5.7” MONO LCD (320X240) CCFL Backlight

 

 

MENU

 

Display

Type                    Dots, Vectors

Format                 X-Y, Y-T

GRID                   Full, Cross, Board

Contrast              Control possible

SAVE/RECALL

10 Setups, 10 Waveforms.   This function is able to save waveform and setting state of present working environment and recall by the user.  Factory setup and recall

UTILITY

Self Calibration,  System condition.

Cursor

Type :  time, frequency, voltage.       Source  :  CH1, CH2.

 

Acquire

Peak detect  :  5µs/div ~ 5s/div(ON/OFF)

Average  : 2 ~ 128

Persistence  :  0.25µs/div ~ 0.1s/div (ON/OFF)

Measure

Max. 10 parameter auto measurement (pk-pk, RMS, Mean, Frequency, Rising time, Falling time, Period, Positive width, Negative width, Duty)

 

 

HOT-KEY

AUTO SET

Vertical, horizontal & Trigger setting

RUN/STOP

Waveform hold

SINGLE

Bandwidth 20MHz

HARDCOPY

Hardcopy through printer port or RS-232C port for thermal printer

 

INTERFACE

RS-232C

Flow control  :  XON / XOFF, HARDWARE

DATE BIT  :  8, 7

STOP BIT  :  1

PARITY  :  NONE, EVEN, ODD

BAUD RATE  :  1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

SPP

Standard Parallel Port, PCL 3 support Printer (Hardcopy)

USB

Ver. 1.1

 

POWER

Power Supply

90V AC ~ 250V AC

Frequency

48Hz ~ 440Hz

Power Consumption

35W

WEIGHT

 

Approx 5.5kg

SIZE

 

338(W) X 167(H) X 370(L) mm

EMC

 

CE (EN 61326)

SAFETY

 

CE (EN 61010-1), meet UL 3111-1

 

 

AMBIENT CONDITION

Temp Range for Rated Operation

+10°C to +35°C (+50°F to +95°F)

Max. Ambient Operating Temp

0°C to 40°C (+32°F to +104°F)

Max. Storage Temp

-10°C to 60°C (+14°F to +140°F)

Humidity Range for Rated Operation

45% to 85% RH

Max. Ambient Operating Humidity

35% to 85% RH

 

 

 

 

 

Send mail to sales@tecstar.co.uk. Main web page links: www.tecstar.co.uk  www.starcom1.com
Last modified: 10-09-04