Oscilloscope
CS-5370P

 
 

Outline
The CS-5370P is 2-channel Oscilloscope developed with concepts of high function design・high accuracy and easy operation. The panel layout never diminishes the intuitive and high-speed response provide fatigue free operation even after long-hours of use. CS-5370P incorporating readout function offers you parameter measurement and auto setup functions enabling to measure AC voltage (Vp-p)・DC voltage・frequency and period. CS-5370P is provided with full features including ア2% high-accuracy measurement・delay sweep function・automatic triggering and high intensity・high-resolution CRT. CS-5370P with high-performance will surely assist you in many kinds of field activities.
Features
Programmable function
Internal non volatile program memory allows programmed sequences of up to 100 steps.
Optional RS-232C or GP-IB interface card enable bus controlled set up and waveform adjustment.

Parameter Auto Measurement Function
It is possible to measure the voltage, frequency and period automatically just input the signal. Especially for voltage measurement, measurement mode is automatically selected according to the input selector. For example, when the AC input is selected, "Peak-to-Peak" voltage is automatically measured, and when the DC input is selected, DC voltage is measured automatically.

Auto Setup Function
By pressing the AUTO SET key, the voltage range and time range are selected automatically.

Cursor Measurement Function
The cursor measurement function allows a high accuracy measurement of signal values. When the probes are used, its attenuation ratio can be converted automatically. It is also possible to measure the voltage value and phase differences. When the delay sweep is used, the delay time is also displayed, enabling an accurate measurement results without any errors due to visual checks in conventional systems.

High-Sensitivity Design with Vertical Axis of 1 mV/div
The vertical axis sensitivity can be varied continuously from 1 mV/div. to 5 V/div. using the 1-2-5 step attenuator. The 1 mV/div. position is very useful to measure low-level and complicated signals. (Frequency response at 1 mV/div. and 2mV/div are DC to 20 MHz (-3 dB)).

Automaticv Sync (FIX) Function
With this function, the synchronization level is automatically controlled by tracking the amplitude of the waveform to maintain the sync lock status. This function eliminates annoying and complicated synchronization operations.

Easy Operation Panel Layout
The CS-5370P used touch switches and LEDs.

Delayed sweep with waveform partial magnification capability
The main (A) sweep waveform in which the magnified section is brightened by intensity modulation and the delayed (B) sweep waveform which shows only the magnified section can be observed simultaneously. This is a real alternate delayed sweep.

High-Accuracy ア 2% Design for More Precision Measurement
In order to obtain highly reliable measurement results, the vertical axis sensitivity and sweep time for the main circuit is maintained within ア 2% precision. Other specifications also guarantees the rated values (under temperature conditions of 10 to 30ーC, humidity of 85% or less).

Square-Type 150 mm CRT with Self-Illuminated Light and Inside Scale (17kV)
A large-sized, square, dome-mesh type CRT with rear accelerator is employed. It features both high intensity and high resolution while providing accurate measurements without parallax view. The auto focus circuit is also incorporated to display sharp waveforms at all times.

Single sweep for observations of single-shot channel
The single sweep function is powerful in measurement of single-shot or sudden channel. Waveform photography using a camera is as easy as ordinary, visual observations. It is easy not only for observations during normal visual inspections but also for camera shots of the waveforms.

Variable hold-off allowing observation of waveforms with complicated cycle
Signals which are hard to be synchronized due to complicated repetition cycles, for example digital signals and video signal bursts, can be synchronized stably by converting them into the hold-off time.

High-Accuracy Calibration Signals
A calibration signal output is provided to output the highly accurate frequency of ア 0.1% and voltage accuracy of ア 1%, enabling checking of the measurement precision at any required time.

CH1 signal output connector
The CH1 signal output is obtained by branching the input signal in the middle of the signal line. As this connector outputs the input signal at a rate of 50 mV/div, connecting a frequency counter makes it possible to measure the frequency of a very low signal while observing its waveform

Wide Dynamic Range and Distortion-Free Accurate Waveform Display
Its wide dynamic range having greater margins assures the linearity of the waveforms displayed on the CRT, providing highly accurate waveform displays without any distortion up to the upper frequency limits.

SPECIFICATION
 
SPECIFICATIONS
CRT Type/accelerating voltage 150 mm rectangular with iinternal graticule 8 ラ 10 div. (1 div.=10mm) /approx. 17 kV 
Vertical Axis (CH1, CH2)  
Sensitivity 5 mV to 5 V/div. ア 2%, 1 mV, 2 mV/div. ア 5%, 1-2-5 step, 12 ranges, fine adjustable within the selected range
Input Impedance 1 MΩ ア 1%, approx. 20 pF
Frequency Response 5 mV to 5 V/div. DC: DC to 100 MHz (within -3 dB)
AC: 5 Hz to 100 MHz (within -3 dB)
1 mV, 2 mV/div. DC: DC to 20 MHz (within -3 dB)
AC: 5 Hz to 20 MHz (within -3 dB)
Rising Time 5 mV to 5 V/div.: approx. 3.5 ns
1 mV, 2 mV/div.: approx. 17.5 ns
Signal Delay Time Leading edge can be confirmed using a square wave that has a rising time of less than this unit
Crosstalk -40 dB (at 1 kHz)

Max. Input Voltage

800 Vp-p or 400 V (DC AC peak, 1 kHz)
Vertical Axis  
Operation Mode CH1, CH2, ADD, ALT, CHOP
Chopping Frequency Approx. 250 kHz
Polarity Inversion CH2 only
Horizontal (CH2 Input)  
Sensitivity 5 mV to 5 V/div. ア 3%, 1 mV, 2 mV/div. ア 5%, 1-2-5 step, 12 ranges, fine adjustable within the selected range
Input Impedance Same as vertical axis (CH2)
Frequency Response DC: DC to 1 MHz ( -3 dB), AC: 5 Hz to 1 MHz ( -3 dB)
X-Y Phase Difference Less than 3ー at 100 kHz
Operation Mode Switchable to X-Y mode with H.MODE key CH1: Y axis, CH2: X axis
Max. Input Voltage Same as vertical axis (CH2)
Sweep  
Sweep Mode A, ALT, B, X-Y
Sweep Time A Sweep 0.5 s to 50 ns/div. ア 2%, 1-2-5 step, 22 ranges, fine adjustable within the selected range
B Sweep 50 ms to 50 ns/div. ア 2%, 1-2-5 step, 19 ranges
Sweep Magnification ラ 10 ア 5%, (ア 8% at 0.5 オs/div. )
Linearity ア 3% (ア 5% at ラ 10 MAG mode)
Hold Off A Sweep, continuously variable from NORM position
Trace Separation B Sweep is continuously variable ア 4 div. with respect to A sweep. 
Delay Sweep Mode Continuous delay (After Delay), Synchronous delay (B TRIG'D): Synchronized with trigger signal
Delay Time Continuously variable from 0.2 div. to 10 div. (0.5s/div. to 50ns/div.)
Delay Time Error ア (3% of setting value 1% of full scale) (0 to 300 ns)
Delay Jitter 20000 (10 times of A Sweep setting value) : 1 (at A Sweep 1 ms/div, B Sweep 1 オs/div)
Triggering Mode  
Trigger Mode AUTO, NORM, FIX, SINGLE, RESET
Trigger Sources VERT, CH1, CH2, LINE
Trigger Coupling AC, HF-REJ, DC, TV-F, TV-L
Trigger Sensitivity (NORM MODE) Coupling Frequency NORM FIX*
AC 10Hz to 50MHz 1.0 div 1.5 div
50MHz to 100MHz 1.5 div 2.0 div
HF-REJ 10Hz to 10kHz 1.0 div 1.5 div
10 kHz or more > min > min
DC DC to 50MHz 1.0 div 1.5 div
50MHz to 100MHz 1.5 div 2.0 div
TV-F, TV-L Composite video signal 1.5 div  
(Above values are obtained with the signal input of: AUTO: 40 Hz or more, FIX: 50 Hz or more
Internal sensitivity indicated as the amplitude on the CRT. Sensitivity in HF-Rej mode ">min" denotes the amplitude required for synchronization will increase.)
Calibration Signal  
Waveform Square wave
Polarity Positive
Amplitude 1 Vp-p ア 1%
Frequency 1 kHz ア 0.1%
Intensity Modulation  
Input Voltage Dims at TTL high level ( 5V)
Input Impedance Approx. 10 kΩ
Frequency Response DC to 5 MHz
Max. Input Voltage 84 Vp-p or 42 V (DC AC peak, 1 kHz)
CH1 Signal Output(50Ω Load)  
Output Voltage Approx. 50 mVp-p/div.
Output Impedance Approx. 50Ω
Frequency Response 5 mV to 5 V/div. 100 Hz to 100 MHz (-3 dB)
1 mV, 2 mV/div.  100 Hz to 20 MHz (-3 dB)
Trace Rotation Enables trace rotation adjustment by semi-fixed controller on the panel.
Readout Section  
Panel Setup Value CH1, CH2 scale factor (with probe detection), V-UNCAL, ADD, INV, 
A/B Sweep scale factor (MAG conversion, "*" is displayed in MAG mode), X-Y, Sweep UNCAL, DELAY, TIME, B TRIG'D
Cursor Measurement (ΔV1 only in X-Y mode) ΔV1: Voltage display by converting CH1 scale factor 
ΔV2: Voltage display by converting CH2 scale factor
ΔT : Time display by converting A Sweep scale factor
Δ1/T: Frequency display by converting Sweep scale factor
Volts/Div or Time/Div UNCAL mode RATIO: Voltage ratio, time ratio display with 5 div. on the CRT as 100% PHASE: Phase difference display with 5 div. on the CRT as 360ー
Resolution/Measurement Error 10 bits/ア 4%
Measuring Range Vertical More than ア 3.6 div. from the center of CRT
Horizontal More than ア 4.6 div. from the center of CRT
Parameter auto setting function Each parameter is measured and displayed for the signal selected as the trigger signal source from CH1 or CH2
Frequency (FRQ) Mode selectable in Cursor mode. Measured with internal counter to be displayed
Frequency Range 2 Hz to 100 MHz
Effective Digits/Accuracy 3 digits/0.01% ア 1 digit
Measurement Sensitivity Same as trigger sensitivity
Period (PER) Mode selectable in Cursor mode. Measured with internal counter to be displayed
Measurement Range 0.5 s to 10 ns
Effective Digits/Accuracy 3 digits/0.01% ア1 digit
Measurement Sensitivity Same as trigger sensitivity
AC Voltage (Vp-p) Mode selectable in Cursor mode. Peak-to-peak voltage is measured and displayed
Measurement Range 0.5 div. to Effective CRT area
Frequency Range 10 Hz to 100 kHz
Effective Digits/Accuracy 3 digits/10 Hz to 40 Hz: ア {8% attenuator setup value (V/div) ラ 0.04 div}
40 Hz to 100 kHz: ア {3% attenuator setup value (V/div) ラ 0.04 div}
DC Voltage (DCV) Mode selectable in Cursor more. Average DC voltage is measured and displayed
Sensitivity 0.5 div. to Effective CRT area
Effective Digits/Accuracy 3 digits/ア {3% attenuator setup value (V/div) ラ 0.04 div}
Auto Setup For CH1, CH2, Vertical axis attenuator, Sweep range, Vertical position, Horizontal position are automatically setup
Period 1.5 to 5 periods (H.Variable,: CAL mode, for input signal up to 10 MHz)
Amplitude 2 to 4 div. (1 to 2 div. for 2-channel)
Frequency (Size wave) 50 Hz to 100 MHz
Position Vertical axis: 1 channel ; almost center of CRT, 2 channel ; CH1 approx. 2 div., CH2 approx. -2 div. from the center of CRT Horizontal axis: starts from left edge of CRT scale
Backup Panel setup values are backed up by built-in battery. Battery service life approx. 30,000 hours (with room temperature)
Programable Function  

Program capacity

Maximum 100 steps (Possible to divide up to 5 groups.)
Power Supply & Others  
Power Requirements  
Input Voltage AC 100/120/220/230 V (ア10% ), 50 Hz / 60 Hz
Power Consumption Max. 62W, 76 VA
Insulator Voltage AC 1.5 kV, 1 minute
Insulator Resistance More than 100MW at DC 500 V
Dimensions (W x H x D) 305 ラ 150 ラ 400 mm /(344 ラ 165 ラ 459 mm, Maximum dimensions)
Weight Approx. 9.6 kg
Operating Environment (limited as indoor use)  
Overvoltage Category/Altitude/Pollution II / 2000 m / 2
Specification Guaranteed  
Temperature & Humidity 10 to 35ーC, 85% or less (with no condensation)
Operation/Storage  
Temperature & Humidity 0 to 40ーC, 85% or less (with no condensation)/ -20 to 70ーC, 85% or less (with no condensation)
Accessories Operation Manual (1)/Adjusting Screwdriver (1)/Power Supply Cable (1)

Probe

PC-51 (2)
Applicable Standards  
Safety Standard EN61010-1 & A2 (1995)
EMI EN55011 (1991) Class B, FCC 47 CFR, Part 15, Sub-Part B, Class B
Immunity IEC801-2 (1991) 8kVAD, IEC801-3 (1984) 3V/m, IEC801-4 (1998)



 

 

 

 

 