Home Up Contact On Line Order Site Map
T: +44 (0)1480 399499 e-mail:sales@tecstar.co.uk  www.tecstar.co.uk F: +44(0)1480 399503 
European distributor for Kenwood & Tecstar test and measurement, PrismSound audio analysers.

 

 

CS 5100 & CS 6100 Oscilloscopes

The CS 5100 & CS 6100 Oscilloscopes offer bandwidth of 100MHz, a Dual time base and cursor readout which makes it ideal for applications requiring good quality and performance but at a low price. These Oscilloscopes are ideal for areas such as production line, development, service and education. CS 6100 has four channels and CS 5100 has two channels with comprehensive triggering and are supplied complete with 2 high quality probes.

·        100MHz Bandwidth.
·        HF/LF Reject Trigger Filters.
·        Auto Set Function.
·        Frequency Counter Function (Only on Auto set).
·        4 Channels, 8 Traces (CS 6100).
·        2 Channels, 4 Traces (CS 5100).
·        Readout Cursor Function.
·        5ns/div Fast sweep rate.
·        CH1 Output.
·        400V MAX. Input Voltage.
·        Delayed sweep function
·        Hold off Function
·        Dual Time Base

                                                                                   CS 6100                                         CS 5100

 
 
 
CRT

Configuration and Useful Screen

6-inch rectangular screen with internal graticule: 8x 10div(1div=1cm), marking for measurement of rise time, 2mm subdivisions along the central axis

Acceleration Potential

+11.5kv approx. (ref. Cathode)

Phosphor

P31 (Standard)

Focusing

Possible (with auto-focus correction circuit)

Trace Rotation

Provided

Scale Illumination

Variable

Intensity Control

Provided

 

Z-AXIS INPUT (Intensity modulation)

Input signal

Positive going signal decreases +5Vp-p or more signal cases noticeable modulation at normal intensity settings

Bandwidth

DC to 2MHz (-3dB)

Coupling

DC

Input Impedance

20kW -30kW  typical

Maximum Input Voltage

30V (DC + peak AC)

 
 
 
 
 
 
 
VERTICAL

DEFLECTION

Bandwidth

(-3dB)

DC coupled

DC to 100MHz (2mV/DIV:DC to 50MHz)

AC coupled

10Hz to 100MHz (2mV/DIV:10Hz to 50MHz)

Modes

CH1, CH2, ADD, DUAL, ALT, CHOP, CH2 INV. QUAD

CH1, CH2, DUAL, ADD, ALT, CHOP, CH2 INV.

Deflection Factor

2mV/Div to 5V/Div in 11 calibrated steps of 1-2-5 sequence. ( For CS 6100: CH3, CH4:0.1V/DIV, 0.5/DIV) Continuously variable between steps at least 1:2.5

Accuracy

±3%

Input Impedance

Approx. 1MW in parallel with 25pF

Maximum Input Voltage

Direct: 400V (DC+ peak AC), with probe: refer to probe specification

Input Coupling

DC-GND-AC

Rise Time

3.5ns or less (2mV/DIV: 7ns or less)

CH1 Out

50mV/Div into 50W : DC to 20MHz(-3dB)

Polarity Inversion

CH2 Only

 

 
HORIZONTAL

DEFLECTION

Display Mode

A,ALT,B,B TRIG’ D, X-Y

Time Base A

0.05us/Div to 0.5s/Div in 22 calibrated steps of 1-2-5 sequence, Uncalibrated continuous control between steps at least 1:2.5

Hold-off Time

Variable with the hold-off control

Time Base B

0.05us/div to 50ms/div in 19 calibrated steps of 1-2-5 sequence

Delayed Sweep Position

1div or less – 10div or more

Delay Time Jitter

Better than 1:10,000

Sweep Magnification

10 times (Maximum sweep rate: 5ns/div)

Accuracy

±3%, ±5% (0°C to 40°C), additional error for magnifier ±2%

 

 

 

 

 

 

TRIGGER

SYSTEM

Modes

AUTO, NORM, TV, SINGLE

Source

LINE, VERT, CH1, CH2, CH3, CH4

LINE, VERT, CH1, CH2

Coupling

AC,DC,HF REJ,LF REJ, TV-V, TV-H

Slope

+ or -

 

Sensitivity and Frequency AUTO(30Hz or more), NORM

 

20Hz – 2MHz

2MHz – 40MHz

INT

0.5div

1.5div

EXT

0.1Vp-p

0.3Vp-p

VERT

0.5div

3.0div

TV-V, TV-H

At least 1div or 1.0Vp-p

External Trigger Input Impedance

1MW in parallel with approx. 25pF

Maximum Input Voltage

400V (DC+ peak AC)

 
X-Y

OPERATION

X-Axis

(same as CH1 except for the following)

Deflection factor; same as that of CH1 / Accuracy: ±6% / Frequency response: DC to 2MHz(-3dB)

Y-Axis

Same as CH2

X-Y Phase Difference

3° or less (at DC to 100kHz)

 

READOUT

FUNCTION

Cursor readout function

DV, DT, D1/T

Auto setup

Enable

Frequency Counter Displays

Enable (only on Autosetup)

Panel setting displays

AC/DC/GND, V-MODE, CH2 Invert, VOLTS/DIV, * 10MAG, H-DSP MODE, TIME/DIV, TRG COUPLING, TRIG SOURCE.

Effective cursor range from centre graticule

Vertical: within ±3div / Horizontal: within ± 4div

Resolution

1/25 div

CALIBRATOR

Probe Adjustment

Approx, 1KHz 0.5Vp-p (±2%)Square wave, duty ratio: 50%

 
POWER

SUPPLY

Line Voltage Range

90~250VAC(fuse:1A 250V)

Line Frequency

48 / 440Hz

Power Consumption

Max. 50W

PHYSICAL

CHARACTERISTIC

Weight

8kg

Size

328mm(W) x 153mm(H) x 392mm(L)

ENVIRONMENTAL

CHARACTERISTIC

Temperature

Temperature range for rated operation: +10°C to +35°C (+50°F to +95°F)

Max, ambient operating temperature: 0°C to +40°C (+32°F to +104°F)

MAX, storage temperature: -20°C to 70°C (-4°F to +158°F)

Humidity

Range for rated operation:45% to 85% RH / Max. Ambient operating humidity : 35% to 90% RH

OTHERS

Accessories supplied

Operator’s manual, Spare fuse, Power cord, Test probe.

 

 

 

 

 

 

Send mail to sales@tecstar.co.uk. Main web page links: www.tecstar.co.uk  www.starcom1.com
Last modified: 10-09-04